-
Jake MillerWe took a chance on inverters-vfd.com for a critical VFD replacement on our assembly line. The product was not only a perfect match but also more affordable than our previous supplier. Its stability has eliminated our frequent tripping issues. An outstanding value and a reliable partner for industrial components. -
Sarah ChenThe technical team at inverters-vfd.com was invaluable. I described our application for a servo motor, and they recommended a model with superior dynamic response. Installation was seamless, and the precision has improved our cycle times. Expert guidance and a high-performance product! -
David "Big D" KowalskiOur order for multiple PLC units and HMIs was fulfilled accurately and shipped with astonishing speed. Since integrating them, our control system's communication is more robust. We're impressed by the logistics and the solid performance of these components. A hassle-free experience all around. -
Emily WhiteWe required a low-noise spindle motor for a sensitive testing environment. The unit we purchased operates whisper-quiet and maintains consistent torque. The quality exceeds some big-name brands we've used, at a fraction of the cost. Exceptional for specialized applications.
Industrial Medium Voltage Drive with 99 Percent Efficiency for Massive kWh Cost Reduction in Heavy Industries
Contact me for free samples and coupons.
WhatsApp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
x| Rated Voltage Of Grid Side | 2: 1900V 3: 3300V 6: 6600V A: 10kV | Rated Voltage Of Motor Side | 3: 3300V 6: 6600V A: 10kV |
|---|---|---|---|
| Power | 10: 10MVA | Rectification Method | P: PWM D: Diode Basic Rectification |
| Common Bus Rectification Method | Blank: Single Rectification 2: Double Rectification | Common Bus Inverter Method | Blank: Single D: Double Inverter T: Triple Inverter |
| Highlight | Industrial medium voltage drive,Variable frequency converter with 99% efficiency,Heavy industry kWh cost reduction drive |
||
HD8000 series VFD is a high-power drive system includes AC-DC-AC comverter and DC-AC common DC bus multi-axis motor drive unit. The maximum power can reach 30MVA for single machine and 60MVA for parallel operation. Its modular hardware and engineering software design concept enables it to operate for various complex conditions.
HD8000 series VFD adopts presspack IGCTand Diode as well as liquid cooling method, the whole machine meets the protection level IP54 and it has super environmental adaptability, high reliability, excellent heat dissipation performance and small volume, there are two-quadrant and four-quadrant rectification solutions.
- Characteristics: single/multiple axis drive, IP54 protection, two-quadrant/four-quadrant
- Design: modular design
- Rectification: multi-pulse basic rectification, smart rectification and PWM rectification
- Voltage rate: 1900V3000V (3300V), 6000V, (6600V), 10000V
- Maximum power: 30MVA (single) 60MVA (parallel)
- Compitable motor: asynchronous induction motor, permanent magnet synchronous motor, Electrically excited synchronous motor
- Control method: V/F, close-loop vector control with sensor, open-loop vector control without sensor
- Cooling: water cooling
- Metallurgical Engineering
- Oil and Gas Transportation
- Testing Platform
- Renewable Energy
- Rail Transportation
- Mining&Lifting
- Marine Equipment
- LNG
- Power Source
- Energy Storage
| HD8000 Technical Specifications | ||||||||||||||
| HD8000 | 3306 | 3308 | 3310 | 3312 | 2624 | AA30 | 6640 | AA60 | ||||||
| R Basical ectification | Input voltage | 3300V | 1900V | 10kV | 6600V | 10kV | ||||||||
| Input frquency | 45Hz-66Hz | |||||||||||||
| Overload | 110%@ rated current, 120%@ rated current 60s | |||||||||||||
| Efficiency | ≥99% | |||||||||||||
| Power factor | ≥0.95 (Rated current, equipped with 2% AC input reactor) | |||||||||||||
| Protection | overload protection, overheat protection, short circuit protection, fault pre-judgment, etc | |||||||||||||
| RecPWM tification |
Input frquency | 45Hz-66Hz | ||||||||||||
| Overload | 110%@ rated current, 120%@ rated current 60s | |||||||||||||
| Efficiency | ≥98.5% | |||||||||||||
| Power factor | adjustable (default 1) | |||||||||||||
| Protection | overload protection, overheat protection, short circuit protection, fault pre-judgment, etc | |||||||||||||
| Inverter | Output voltage | 3300V | 6600V | 10kV | 6600V | 10kV | ||||||||
| Max output frequency |
110Hz |
|||||||||||||
| Speed stable accuracy | OLVC: 0.01%, CLVC: 0.01% | OLVC: 0.01%, CLVC: 0.01% | ||||||||||||
| Speed pulse | OLVC: 0.2%, CLVC: 0.1% | OLVC: 0.4%, CLVC: 0.2% | ||||||||||||
| Start torque | OLVC: 150%, CLVC: 200% | OLVC: 130%, CLVC: 150% | ||||||||||||
| Torque control | V/F: Yes, OLVC: Yes, CLVC: Yes | V/F: Yes, OLVC: Yes, CLVC: Yes | ||||||||||||
| Torque accuracy | OLVC: 5%, CLVC: 2% | OLVC: 5%, CLVC: 2% | ||||||||||||
| Torque response time | OLVC: 5ms, CLVC: 5ms | OLVC: 5ms, CLVC: 5ms | ||||||||||||
| Rotating response time | OLVC: 100ms, CLVC: 100ms | OLVC: 150ms, CLVC: 150ms | ||||||||||||
| Dynamic drop equivalent | OLVC: 0.5%*s, CLVC: 0.25%*s | OLVC: 1%*s, CLVC: 0.5%*s | ||||||||||||
| Overload | 110%@rated current, 120%@rated current 60s | |||||||||||||
| Environment | Temperature | inlet temperature ≤40 | ||||||||||||
| Altitude | ≤4000m (2000m~4000m de-rating) | |||||||||||||
| Mechanical Data | IP protection | IP54 | ||||||||||||
| Cooling | Water cooling | |||||||||||||
| Anti corrosion | C4-M | |||||||||||||
| Module | Grid Voltage | Motor Voltage | Power | RatedI | Max f | Size (W*D*H) (mm) | Note | |||||||
| HD8000-3306 | 3300V | 3300V | 6MVA | 1050A | 110Hz | 4600*1300*2200 | Contains water cool cabinet | |||||||
| HD8000-3308 | 8MVA | 1400A | ||||||||||||
| HD8000-3310 | 10MVA | 1750A | ||||||||||||
| HD8000-3312 | 12MVA | 2100A | ||||||||||||
| HD8000-2624 | 1900V | 6600V | 24MVA | 2100A | 7800*1300*2200 | |||||||||
| HD8000-AA30 | 10kV | 10kV | 30MVA | 1750A | 10600*1300*2200 | |||||||||
| HD8000-6640 | 6600V | 6600V | 40MVA | 3500A | 15600*1300*2200 | |||||||||
| HD8000-AA60 | 10kV | 10kV | 60MVA | 3500A | 21200*1600*2200 | |||||||||
-
High compatibility with European industrial voltage standards (3300V–10kV).
-
Advanced overload protection ensures operational safety in automated manufacturing.
-
IP54 rating ideal for humid or dusty environments.
-
Water-cooling system supports continuous operation in high-temperature settings.
-
Precision torque control (OLVC/CLVC) for high-speed machinery.
-
Compliance with strict German engineering and safety norms.
-
Modular design allows easy integration into existing Siemens or Bosch systems.
-
Energy efficiency ≥99% reduces operational costs in energy-intensive industries.
-
Robust short-circuit and overheating protection for heavy-duty applications.
-
Suitable for oil & gas, mining, and HVAC systems with wide input voltage range.
-
High-altitude operation up to 4000m supports use in Rocky Mountain regions.
-
Compatible with NEMA and IEEE standards.
-
Easy maintenance and fault pre-judgment reduce downtime.
-
Scalable from 6MVA to 60MVA for growing industrial demands.
-
Supports both V/F and vector control for versatile motor compatibility.
-
Compact footprint saves space in large industrial plants.
-
High power factor (≥0.95) aligns with Japan’s energy-saving regulations.
-
Precision speed control (0.01% accuracy) for robotics and CNC machines.
-
Resilient to frequent power fluctuations (45–66Hz).
-
Compact and modular design ideal for space-constrained facilities.
-
Corrosion-resistant (C4-M) for coastal industrial zones.
-
Silent water-cooling operation suitable for noise-sensitive areas.
-
Compatible with Japanese motor standards (e.g., Toshiba, Mitsubishi).
-
Long service life with minimal maintenance.
-
Built to withstand high ambient temperatures (up to 40°C inlet).
-
Dust and moisture resistance (IP54) ideal for textile and cement industries.
-
High overload capacity (120% for 60s) handles unstable grid conditions.
-
Easy integration with local motor and grid standards.
-
Cost-effective operation with ≥98.5% efficiency.
-
Supports both 6600V and 10kV motor systems.
-
Robust mechanical construction for rugged environments.
-
Local service support readiness with modular spare parts.
-
Suitable for mining and mineral processing with high torque output.
-
Operates reliably in remote and high-altitude locations.
-
Water-cooled design performs well in hot, arid climates.
-
Complies with AS/NZS standards for industrial safety.
-
High starting torque (up to 200%) for conveyor and crusher systems.
-
Fault pre-judgment minimizes unscheduled stoppages.
-
Easy to install and commission with local technical support.
-
Energy-efficient operation reduces carbon footprint.


