All Products
VFD Motor Converter Digital Frequency Inverter VFD Inverter With Torque Lifting 0.0-30.0%
Input Frequency Accuracy: | Digital: 0.01Hz, Analog: 0.01Hz |
---|---|
Control Method: | V/F, OLVC (Open-Loop Vector Control), CLVC (Close-Loop Vector Control) |
Torque Pulsation: | ≤5%, Vector Control |
HV500 Low Voltage Engineering Single-Drive Inverter 220V 380V 690V 2.2kW~560kW
Protection Grade: | IP20 |
---|---|
Cooling Way: | Forced Air Cooling |
Efficiency: | 5.5kW~22kW: ≥93%; Above 30kW: ≥95% |
220V 380V 690V HV500 VFD Frequency Inverter Low Voltage Engineering Single-Drive Inverter 2.2kw-560kw
Unbalance Degree Of Uin: | ≤3% |
---|---|
Control Method: | V/F, OLVC (Open-Loop Vector Control), CLVC (Close-Loop Vector Control) |
Speed Regulation Precision: | OLVC 0.2%, CLVC 0.01% |
LCD Panel Low Voltage VFD 24V DC Input Power Supported 2.2kw 560kw 380V 690V
Motor Type: | Asynchronous Motor, Synchronous Motor |
---|---|
Control Method: | V/F, OLVC (Open-Loop Vector Control), CLVC (Close-Loop Vector Control) |
Acceleration And Deceleration Time: | 0.0s~3200.0s, 0.0min~3200.0min |
220V 380V 690V VFD Frequency Inverter 2.2KW 560KW Standard LCD Panel To Improve User Experience
Start Torque: | VF: 100% (0.5Hz), OLVC: 150% (0.5Hz), CLVC: 180% (0Hz) |
---|---|
Acceleration And Deceleration Curve: | Straight, S Curve |
Motor Type: | Asynchronous Motor, Synchronous Motor |
HV500 VFD Frequency Inverter 220V-690V Low Voltage Drive for Industrial Applications
Unbalance Degree Of Uin: | ≤3% |
---|---|
Control Method: | V/F, OLVC (Open-Loop Vector Control), CLVC (Close-Loop Vector Control) |
Speed Regulation Precision: | OLVC 0.2%, CLVC 0.01% |
High-Performance HV500 VFD 2.2kW-560kW, 220V-690V Single Drive Inverter
Unbalance Degree Of Uin: | ≤3% |
---|---|
Control Method: | V/F, OLVC (Open-Loop Vector Control), CLVC (Close-Loop Vector Control) |
Speed Regulation Precision: | OLVC 0.2%, CLVC 0.01% |
Energy-Efficient HV500 VFD Low Voltage Engineering Solution for 220V-690V Systems
Motor Type: | Asynchronous Motor, Synchronous Motor |
---|---|
Control Method: | V/F, OLVC (Open-Loop Vector Control), CLVC (Close-Loop Vector Control) |
Acceleration And Deceleration Time: | 0.0s~3200.0s, 0.0min~3200.0min |
Low Voltage Engineering Single-Drive Inverter 2.2kW-560kW Output frequency 0~600Hz Output voltage 0V-Input voltage
Input Voltage: | Input Voltage: 380V (-15%) To 480V (+10%) Phase: Three-phase |
---|---|
Input Power Frequency: | 50Hz/60Hz ±5% |
Output Voltage: | 0V~Input Voltage |
Variable Frequency Drive Inverter Motor Vfd Drive With Dynamic Speed Reduction Torque Lifting
Oem: | Yes |
---|---|
Torque Pulsation: | ≤5%, Vector Control |
Dynamic Speed Reduction: | OLVC<0.5%*s, CLVC<0.3%*s |