All Products
Modular Design Low voltage VFD HD2000 Voltage Levels 400V 690V 1140V 1380V
Model: | HD2000-C-10-12 |
---|---|
Special Function: | Multi Step Speed |
Oem: | Acceptable |
1400kw 11200kw HD2000 Series Low Voltage Engineering Inverter Air-cooled 400V 600V VDF
Model: | HD2000-C-10-12 |
---|---|
Special Function: | Multi Step Speed |
Oem: | Acceptable |
Reliable and Robust VFD Variable Frequency Drive HD2000 Inverter with Modular Hardware and Software Design
Keyboard: | LED/LCD |
---|---|
Rated Power: | 0.4-750KW |
Outtype: | Triple |
220V 380V 690V VFD Frequency Inverter 2.2KW 560KW Standard LCD Panel To Improve User Experience
Start Torque: | VF: 100% (0.5Hz), OLVC: 150% (0.5Hz), CLVC: 180% (0Hz) |
---|---|
Acceleration And Deceleration Curve: | Straight, S Curve |
Motor Type: | Asynchronous Motor, Synchronous Motor |
LCD Panel Low Voltage VFD 24V DC Input Power Supported 2.2kw 560kw 380V 690V
Motor Type: | Asynchronous Motor, Synchronous Motor |
---|---|
Control Method: | V/F, OLVC (Open-Loop Vector Control), CLVC (Close-Loop Vector Control) |
Acceleration And Deceleration Time: | 0.0s~3200.0s, 0.0min~3200.0min |
50Hz/60Hz±5% Input Frequency Standard VFD with IGBT Module Heat Protection Design and Built-in DC Reactor
Power Range: | 0.4kW~500kW |
---|---|
Input Voltage Uin: | 200V (-15%) ~ 240V (+10%) 1PH/3PH 380V (-15%) ~ 480V (+10%) 3PH 500V 500V (-15%) ~ 690V (+10%) 3PH |
Input Frequency: | 50Hz/60Hz±5% |
HD2000 Inverter AC-DC-AC Variable Frequency Drive Units Max. Parallel Operation Power 11200kW Air-cooled
Single/Multi-Drive: | Flexible System With Units/cabinets Supporting Two/four Quadrants |
---|---|
Modular Design: | Enables Application Flexibility And Comprehensive System Integration |
Rectifier Units: | Basic/Smart/PWM Rectifier Units For Versatile Power Conversion |
Customized Control Options Variable Frequency Drive Vector and V/F Modes with HD2000 Inverter
Working Efficiency: | Very Good |
---|---|
Oem: | Acceptable |
Analogue Inputs: | 2 |
220V 380V 690V HV500 VFD Frequency Inverter Low Voltage Engineering Single-Drive Inverter 2.2kw-560kw
Unbalance Degree Of Uin: | ≤3% |
---|---|
Control Method: | V/F, OLVC (Open-Loop Vector Control), CLVC (Close-Loop Vector Control) |
Speed Regulation Precision: | OLVC 0.2%, CLVC 0.01% |
Straight-line Type V/F Curve VFD Three Phase 380V-480V Built-in C3 Filter LED Keyboard OLVC Control Mode
Anti Shake Function: | Prevent Accidents Caused By Significant Swinging Of The Load During Acceleration Or Deceleration |
---|---|
Acceleration And Deceleration Curve: | Straight Line, S-curve |
Input Power Frequency: | (50Hz/60Hz)±5% |